-- CIRRUSLOGIC-CNDSP-MIB.my
-- MIB generated by MG-SOFT Visual MIB Builder Version 5.0  Build 250
-- Thursday, January 20, 2005 at 17:11:03
--

	CIRRUSLOGIC-CNDSP-MIB DEFINITIONS ::= BEGIN
 
		IMPORTS
			cobraNet			
				FROM PEAKAUDIO-MIB			
			OBJECT-TYPE			
				FROM RFC-1212;
	
	
	
--
-- Node definitions
--
	
		-- 1.3.6.1.4.1.2680.1.4
		dspExtensions OBJECT IDENTIFIER ::= { cobraNet 4 }

		
		-- 1.3.6.1.4.1.2680.1.4.1
		procMode OBJECT-TYPE
			SYNTAX INTEGER
			ACCESS read-write
			STATUS mandatory
			DESCRIPTION
				"Signal processing mode, 
				  0 - silent;
				  1 - pass through;
				  2 - run; run the user configuration."
			::= { dspExtensions 1 }

		
		-- 1.3.6.1.4.1.2680.1.4.2
		controlRWLength OBJECT-TYPE
			SYNTAX INTEGER
			ACCESS read-only
			STATUS mandatory
			DESCRIPTION
				"Length of read-write control variables"
			::= { dspExtensions 2 }

		
		-- 1.3.6.1.4.1.2680.1.4.3
		controlRWTable OBJECT-TYPE
			SYNTAX SEQUENCE OF ControlRWEntry
			ACCESS not-accessible
			STATUS mandatory
			DESCRIPTION
				"Table of control read-writable variables"
			::= { dspExtensions 3 }

		
		-- 1.3.6.1.4.1.2680.1.4.3.1
		controlRWEntry OBJECT-TYPE
			SYNTAX ControlRWEntry
			ACCESS not-accessible
			STATUS mandatory
			DESCRIPTION
				"Row."
			INDEX { controlRWIndex }
			::= { controlRWTable 1 }

		
		ControlRWEntry ::=
			SEQUENCE { 
				controlRWIndex
					INTEGER,
				controlRWValue
					INTEGER
			 }

		-- 1.3.6.1.4.1.2680.1.4.3.1.1
		controlRWIndex OBJECT-TYPE
			SYNTAX INTEGER (1..65535)
			ACCESS read-only
			STATUS mandatory
			DESCRIPTION
				"Table Index"
			::= { controlRWEntry 1 }

		
		-- 1.3.6.1.4.1.2680.1.4.3.1.2
		controlRWValue OBJECT-TYPE
			SYNTAX INTEGER
			ACCESS read-write
			STATUS mandatory
			DESCRIPTION
				"value of control read-write variable"
			::= { controlRWEntry 2 }

		
		-- 1.3.6.1.4.1.2680.1.4.4
		controlROLength OBJECT-TYPE
			SYNTAX INTEGER
			ACCESS read-only
			STATUS mandatory
			DESCRIPTION
				"Length of read-only control variables"
			::= { dspExtensions 4 }

		
		-- 1.3.6.1.4.1.2680.1.4.5
		controlROTable OBJECT-TYPE
			SYNTAX SEQUENCE OF ControlROEntry
			ACCESS not-accessible
			STATUS mandatory
			DESCRIPTION
				"Table of control read-only variables"
			::= { dspExtensions 5 }

		
		-- 1.3.6.1.4.1.2680.1.4.5.1
		controlROEntry OBJECT-TYPE
			SYNTAX ControlROEntry
			ACCESS not-accessible
			STATUS mandatory
			DESCRIPTION
				"Row."
			INDEX { controlROIndex }
			::= { controlROTable 1 }

		
		ControlROEntry ::=
			SEQUENCE { 
				controlROIndex
					INTEGER,
				controlROValue
					INTEGER
			 }

		-- 1.3.6.1.4.1.2680.1.4.5.1.1
		controlROIndex OBJECT-TYPE
			SYNTAX INTEGER (1..65535)
			ACCESS read-only
			STATUS mandatory
			DESCRIPTION
				"Table Index"
			::= { controlROEntry 1 }

		
		-- 1.3.6.1.4.1.2680.1.4.5.1.2
		controlROValue OBJECT-TYPE
			SYNTAX INTEGER
			ACCESS read-only
			STATUS mandatory
			DESCRIPTION
				"value of control read-only variable"
			::= { controlROEntry 2 }

		
	
	END

--
-- CIRRUSLOGIC-CNDSP-MIB.my
--